AHU Maintenance
Air Handling at Full Performance
Air handling units deliver the air your building actually breathes, so their condition directly affects comfort and air quality. HAVEN FORCE services AHUs including filters, coils, drainage, fans and controls.
Air
Delivery
Filtration
Maintained
Fan & Belt
Care
Drainage
Clear
What We Typically Find
The conditions most often reported before a ahu maintenance scope is developed.
Reduced airflow from the unit
Blocked filters or fouled coils restricting the air path.
Water overflowing the drain tray
Blocked condensate drainage causing leaks and damage below.
Noise and vibration from the AHU
Bearing wear, belt misalignment or loose panels.
Musty smell through the supply air
Biological growth on wet coils and in drain trays.
What This Service Covers
Service Scope
- Filter inspection and replacement
- Coil cleaning and fin combing
- Drain tray and trap clearance
- Fan, bearing and belt inspection
- Damper and actuator checks
- Panel, seal and insulation inspection
- Control and sensor verification
- Airflow measurement and reporting
Suitable For
- Residential Buildings
- Commercial Buildings
- Industrial Facilities
- Retail & Shopping Centers
- Hotels & Hospitality
- Schools & Hospitals
- Warehouses & Large Facilities
- New & Existing Buildings
Key Benefits
- Restores design airflow
- Protects indoor air quality
- Prevents condensate leaks
- Reduces noise and vibration
- Lower energy consumption
- Extends unit life
- Reduces biological growth risk
- Documented service record
Work Methodology
Five controlled stages from first inspection to final quality check.
1
Inspection
Open up and inspect filters, coils, trays, fans and panels.
2
Cleaning
Replace filters, clean coils and clear the condensate tray and trap.
3
Mechanical Checks
Inspect fans, bearings, belts, dampers and actuators.
4
Controls
Verify sensors, control sequences and safety interlocks.
5
Measure & Report
Measure airflow and report condition and recommendations.
Specified To The Condition
Systems are selected according to substrate, exposure and project specification. The final specification is confirmed after a site assessment.
Filter Media
Grades selected to the air quality requirement and changed on schedule.
Coil Cleaning Agents
Non-corrosive cleaners that restore heat transfer safely.
Anti-Microbial Treatment
Applied to trays and coils where growth is a recurring issue.
Questions About AHU Maintenance
Related HVAC & MEP Services
AC Ducting
Clean Air. Comfortable Spaces. Greater Productivity.
ViewHVAC Installation
Systems Installed to Perform
ViewHVAC Maintenance
Planned Care, Fewer Breakdowns
ViewChiller AC Maintenance
Keeping Central Plant Efficient
ViewFCU Maintenance
Comfort at Room Level
ViewDuct Modification
Adapting Air to a New Layout
View