Structural Strengthening by HAVEN FORCE Technical Services in Dubai
Concrete Repair & Protection

Structural Strengthening

Adding Capacity to Existing Structures

Where an element no longer has the capacity required — through deterioration, a change of use or increased loading — it can often be strengthened rather than replaced. HAVEN FORCE installs carbon fibre and steel plate strengthening to engineer's design.

Increased
Capacity

Carbon Fibre
Systems

Engineer
Designed

Minimal
Downtime

Common Problems

What We Typically Find

The conditions most often reported before a structural strengthening scope is developed.

01

Change of use increasing loads

A structure now carrying more than it was designed for.

02

Section loss from corrosion

Reinforcement that has lost area and therefore capacity.

03

New openings cut through members

Penetrations that removed structural material.

04

Excessive deflection or cracking

Signs that an element is working beyond its comfortable range.

Scope & Application

What This Service Covers

Service Scope

  • Structural assessment and design liaison
  • Load testing where specified
  • Substrate preparation and levelling
  • Carbon fibre plate and fabric installation
  • Steel plate bonding where specified
  • Anchorage detailing
  • Protective and fire-rated finishing
  • Inspection and documentation

Suitable For

  • Commercial Buildings
  • Car Parks & Podiums
  • Industrial Facilities
  • Retaining Walls
  • Water Retaining Structures
  • Residential Developments
  • Balconies & Facades
  • Infrastructure Elements

Key Benefits

  • Increases load capacity
  • Avoids demolition and rebuild
  • Fast installation, minimal downtime
  • Very low added weight and thickness
  • Designed and verified by engineers
  • Far cheaper than replacement
  • Documented and inspectable
  • Suits change-of-use projects
Our Process

Work Methodology

Five controlled stages from first inspection to final quality check.

Assessment — Structural Strengthening
1

Assessment

Review the structure with the engineer and confirm the strengthening design.

Preparation — Structural Strengthening
2

Preparation

Grind and level the substrate so the strengthening bonds correctly.

Installation — Structural Strengthening
3

Installation

Bond carbon fibre plates or fabric, or steel plates, as designed.

Anchorage — Structural Strengthening
4

Anchorage

Install end anchorage and detailing to the design requirements.

Protection & Inspect — Structural Strengthening
5

Protection & Inspect

Apply protective or fire-rated finish, then inspect and document.

Materials & Systems

Specified To The Condition

Systems are selected according to substrate, exposure and project specification. The final specification is confirmed after a site assessment.

Carbon Fibre Plate & Fabric

Very high tensile strength with negligible added weight or thickness.

Structural Epoxy Adhesive

Bonds the strengthening to the prepared concrete substrate.

Fire Protection Board

Applied where the strengthening needs a fire rating.

Gallery

Work In Progress

Structural Strengthening — site photograph
View
Structural Strengthening — site photograph
View
Structural Strengthening — site photograph
View
Structural Strengthening — site photograph
View
Full Gallery
FAQs

Questions About Structural Strengthening

For most capacity problems, yes — and it avoids demolition. The engineer confirms it suits your specific case.
Carbon fibre plates add only a few millimetres, so headroom and clearances are barely affected.
Usually yes. The adhesive loses strength at elevated temperature, so a fire-rated encasement is normally specified.