Structural Strengthening
Adding Capacity to Existing Structures
Where an element no longer has the capacity required — through deterioration, a change of use or increased loading — it can often be strengthened rather than replaced. HAVEN FORCE installs carbon fibre and steel plate strengthening to engineer's design.
Increased
Capacity
Carbon Fibre
Systems
Engineer
Designed
Minimal
Downtime
What We Typically Find
The conditions most often reported before a structural strengthening scope is developed.
Change of use increasing loads
A structure now carrying more than it was designed for.
Section loss from corrosion
Reinforcement that has lost area and therefore capacity.
New openings cut through members
Penetrations that removed structural material.
Excessive deflection or cracking
Signs that an element is working beyond its comfortable range.
What This Service Covers
Service Scope
- Structural assessment and design liaison
- Load testing where specified
- Substrate preparation and levelling
- Carbon fibre plate and fabric installation
- Steel plate bonding where specified
- Anchorage detailing
- Protective and fire-rated finishing
- Inspection and documentation
Suitable For
- Commercial Buildings
- Car Parks & Podiums
- Industrial Facilities
- Retaining Walls
- Water Retaining Structures
- Residential Developments
- Balconies & Facades
- Infrastructure Elements
Key Benefits
- Increases load capacity
- Avoids demolition and rebuild
- Fast installation, minimal downtime
- Very low added weight and thickness
- Designed and verified by engineers
- Far cheaper than replacement
- Documented and inspectable
- Suits change-of-use projects
Work Methodology
Five controlled stages from first inspection to final quality check.
1
Assessment
Review the structure with the engineer and confirm the strengthening design.
2
Preparation
Grind and level the substrate so the strengthening bonds correctly.
3
Installation
Bond carbon fibre plates or fabric, or steel plates, as designed.
4
Anchorage
Install end anchorage and detailing to the design requirements.
5
Protection & Inspect
Apply protective or fire-rated finish, then inspect and document.
Specified To The Condition
Systems are selected according to substrate, exposure and project specification. The final specification is confirmed after a site assessment.
Carbon Fibre Plate & Fabric
Very high tensile strength with negligible added weight or thickness.
Structural Epoxy Adhesive
Bonds the strengthening to the prepared concrete substrate.
Fire Protection Board
Applied where the strengthening needs a fire rating.
Questions About Structural Strengthening
Related Concrete Repair Services
Concrete Repair
Restoring Damaged Concrete
ViewCrack Repair
Closing the Path Through Concrete
ViewCorrosion Treatment
Stopping Deterioration at the Steel
ViewMicro Concrete Repair
Flowable Repair for Larger Sections
ViewHoneycomb Repair
Filling Voids Left by the Pour
ViewProtective Coating
Slowing the Next Cycle of Decay
View