Waterproofing

Metal Roof Waterproofing & Recoating

Leakage at overlaps and fastener points, with early-stage corrosion visible along seams of the profiled sheet roof.

Location

Dubai Investments Park

Property Type

Warehouse

Service

Waterproofing

System

Liquid-applied PU membrane, reinforcement fabric, primer

Initial Condition

What We Found

Leakage at overlaps and fastener points, with early-stage corrosion visible along seams of the profiled sheet roof.

Scope of Work

What Was Carried Out

Roof cleaning, corrosion treatment, seam and fastener sealing, application of a UV-resistant liquid membrane over the full roof area.

HAVEN FORCE Solution

How It Was Solved

Seams, laps and fasteners were individually banded with reinforcement fabric before the full-area liquid system was applied.

Materials / System

Liquid-applied PU membrane, reinforcement fabric, primer