Dry Crack Injection
Restoring Dormant Cracks
A dry, non-moving crack can be bonded back together with epoxy so the element regains its structural continuity. HAVEN FORCE injects dormant cracks in slabs, beams, columns and walls to restore strength and close the moisture path.
Dormant
Cracks
Structural
Bond
Full-Depth
Penetration
Permanent
Repair
What We Typically Find
The conditions most often reported before a dry crack injection scope is developed.
Cracking through a structural member
Loss of continuity affecting how load is carried.
Shrinkage cracks in a new slab
Early-age cracking that needs sealing before services are installed.
Cracks admitting moisture to rebar
Open paths that will eventually start corrosion.
Cracking after settlement
Movement that has since stabilised but left the element cracked.
What This Service Covers
Service Scope
- Crack survey and movement monitoring
- Confirmation that the crack is dry and dormant
- Surface cleaning and crack mapping
- Port installation and surface sealing
- Low-viscosity epoxy injection
- Port removal and grinding flush
- Core verification where specified
- Documentation and handover
Suitable For
- Basements
- Retaining Walls
- Construction Joints
- Lift Pits
- Water Tanks & Reservoirs
- Swimming Pools
- Podiums & Underground
- Tunnels & Utility Ducts
Key Benefits
- Restores structural continuity
- Bond stronger than the concrete
- Closes the moisture pathway
- Protects reinforcement
- Permanent and non-shrinking
- Penetrates very fine cracks
- Verifiable by core sampling
- Avoids member replacement
Work Methodology
Five controlled stages from first inspection to final quality check.
1
Inspection
Confirm the crack is dry and has stopped moving, and map its extent.
2
Port Installation
Fix ports along the crack and seal the surface between them.
3
Injection
Inject low-viscosity epoxy from the lowest port until refusal.
4
Finishing
Cure fully, remove ports and grind the surface flush.
5
Verification
Core sample or ultrasonic check where specified.
Specified To The Condition
Systems are selected according to substrate, exposure and project specification. The final specification is confirmed after a site assessment.
Low-Viscosity Epoxy
Capillary action carries it into cracks well below a millimetre wide.
Surface Seal Paste
Contains injection pressure so resin travels along the crack, not out of it.
Injection Ports
Spaced to the element thickness so resin reaches full depth.
Questions About Dry Crack Injection
Related Leakage & Injection Services
Leakage Repair
Stop Leakage. Restore Strength. Protect for the Future.
ViewSeepage Repair
Stop Seepage. Protect Your Space.
ViewPU Injection
Arresting Active Water, Fast
ViewEpoxy Injection
Structural Bonding for Dry Cracks
ViewAcrylic Gel Injection
Curtain Sealing Behind the Structure
ViewConstruction Joint Injection
Sealing the Cold Joint
View